Common faults of Sensor urinal flush valve
release time:
Feb 18,2022
The Sensor urinal flush valve is convenient for maintenance and installation of the induction device, and has a simple and compact structure. At the same time, the water outlet pipe joint at the lower end of the sensor urinal flush valve can be retrofitted with a faucet nozzle, which can be used as a faucet and has multi-purposes and can be used in various occasions.
Common faults of Sensor urinal flush valve:
1. There is induction (the indicator light is on) and no water is produced: The manufacturer of the Sensor urinal flush valve tells you to check whether the filter screen is blocked. If there is, clean it, then disassemble the inside of the solenoid valve for cleaning, and then put it back as it is. After induction by hand, if the electromagnetic If the valve spool has no sound of working (opening and closing), replace the solenoid valve coil
2. There is no induction (the indicator light is not on), and the water is always flowing: the manufacturer of the Sensor urinal flush valve tells you to check whether the power supply is normal.
3. There is induction (the indicator light is on) and the water is always flowing: The manufacturer of the Sensor urinal flush valve tells you to first check whether the water inlet filter is blocked by impurities. The sound of closing, if it works, disassemble the inside of the solenoid to clean it, then put it back as it is.
4. There is a sensor (the indicator light is on) for the amount of water: the manufacturer of the Sensor urinal flush valve tells you to clean the filter screen and the solenoid valve, and then put it back as it is.